• Users Online: 96
  • Home
  • Print this page
  • Email this page
Home About us Editorial board Search Ahead of print Current issue Archives Submit article Instructions Subscribe Contacts Login 
ORIGINAL ARTICLE
Year : 2022  |  Volume : 14  |  Issue : 1  |  Page : 38-41

The safety and efficacy of biceps tenodesis performed using a novel suture anchor


Anne Arundel Medical Center, Annapolis, MD, USA

Correspondence Address:
Dr. Justin J Turcotte
2000 Medical Parkway, Suite 503, Annapolis, MD 21401
USA
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/jotr.jotr_83_21

Rights and Permissions

Introduction: Biceps tendon degeneration or tearing is a significant cause of shoulder discomfort and dysfunction. Biceps tenodesis is commonly performed to treat symptomatic biceps tendon pathology. A variety of fixation techniques can be used including screw fixation, endobutton, or suture anchor techniques. This study examines the patient outcomes when the FOOTPRINT™ Ultra suture anchor system is used for biceps tenodesis. Materials and Methods: Retrospective review of consecutive patients undergoing biceps tenodesis was conducted. All patients underwent biceps tenodesis using the FOOTPRINT™ Ultra suture anchor. The primary endpoint was any device-related complication during the intraoperative or postoperative period. Descriptive and inferential statistics were performed to assess patient characteristics and outcomes. Results: Twenty-nine patients were included in this study; 20 (69.0%) underwent arthroscopic biceps tenodesis and the remainder underwent open surgery. The mean follow-up time was 8.51 ± 5.28 months postoperatively. One patient experienced a postoperative infection within the first 30 days requiring a return to the operating room. Two patients experienced a complication within the first 6 months postoperatively. No patients experienced a device-related complication. No patients experienced a retear of their biceps tendon; two patients experienced a retear to their rotator cuff repair. The mean pain Numeric Rating Scale improved from 5.88 ± 2.58 on a scale of 0–10 preoperatively to 1.94 ± 2.32 postoperatively (P < 0.001). Conclusion: The FOOTPRINT™ Ultra suture anchor appears to be safe for the use in patients undergoing arthroscopic or open biceps tenodesis.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed92    
    Printed2    
    Emailed0    
    PDF Downloaded8    
    Comments [Add]    

Recommend this journal